F10Serious
Whirlpool Dryer F10 Error Code
The thermal fuse has blown due to overheating, preventing the dryer from heating.
Common causes
- Restricted airflow (clogged vent)
- Failed blower motor
- Faulty heat source (element or gas)
How to fix it
- Unplug dryer and locate thermal fuse (usually on blower housing).
- Check fuse continuity with multimeter (should be closed).
- Replace if open, and clean vent system thoroughly.
⚠ When to call a pro: If new fuse blows quickly, there is a serious airflow or heating issue.
Part links are affiliate links — as an Amazon Associate we may earn a small commission at no extra cost to you.