E4Serious

Haier Dryer E4 Error Code

The heater relay on the control board is stuck open or closed.

Common causes

  • Faulty control board relay
  • Heating element shorted causing relay damage
  • Power surge

How to fix it

  1. Unplug the dryer for 10 minutes to reset the control board.
  2. Check the heating element continuity (should be ~10 ohms) – if shorted, replace.
⚠ When to call a pro: Call a technician if the error persists after reset, as control board replacement is likely needed.

Part links are affiliate links — as an Amazon Associate we may earn a small commission at no extra cost to you.

Always unplug the appliance (and turn off the water for washers/dishwashers) before inspecting. These guides are for information only and are not a substitute for a professional repair.